156
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
Install a Coil Driver Board - 180 Deg. Section (500 mm)
If required, reference
Straight Section - Left Coil Driver Board
on page 28, and
Coil Driver Board with a Power Supply Connected
on page 29 during this procedure.
1. Remove the old coil driver board.
Remove a Coil Driver Board - 180 Deg. Section (500 mm)
2. Inspect the new coil driver board, to make sure it contains ten (10) 15 A fuses.
3. Align the coil driver board with the screw holes inside the straight section or
180 deg. section.
4. Secure the coil driver board in position
with fourteen (14) screws.
Make sure that the screw in the upper
left corner of the coil driver board is
nylon.
5. Connect the five (5) coil plugs.
6. Connect the two (2) ribbon cables.
7. Connect the three (3) thermistor connections.
• To prevent electrical board damage from electrostatic discharge
(ESD), use an ESD wrist strap when working with the coil driver
board. An ESD wrist strap prevents the buildup of static electricity.
• During installation, take care not to pinch wires when the coil driver
board screws are installed. This can cause an electrical short.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...