112
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Installation
5. Route the IR reader cable into the back of
the straight section electrical box, using
the supplied knock-out reducer and strain
relief connector.
6. Plug the IR reader cable into the IR reader
connection on the gateway board. It must
be connected to the gateway board of the
SuperTrak conveyance platform section
that the IR reader is mounted on.
7. Slide a pallet in front of the IR reader.
8. Verify that a 1 mm (0.39 in.) gap exists between the IR tag on the pallet and
the IR reader. If required, adjust the air gap adjustment screw to increase or
decrease the gap.
9. Configure the IR reader.