264
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Troubleshooting
7. Set the
Velocity
parameter to 50 mm/s.
8. Click the
Pallet Control
tab.
9. Under
Move to Target
, select a
Target
that is past the section to
be tested and in the direction that
will cause the pallet to travel over
the section to be tested.
10. Select the correct pallet direction (
Left
or
Right
), and then click
Go
.
11. With the SuperTrak power supply power ON, click
Diagnostic
>
Pallet
, and
then click
Enable
Section
for the section being tested and the sections on
each side of it.
Do not enable power to any other sections because this may cause all the
SuperTrak pallets to move around the system.
12. In the left pane, click
System Status/Control
, and then click
Disable
Zone
.
The section passes if the pallet fully travels over the section without producing
an
Excessive Follow Error
fault.
13. Click the
Configuration
tab.
14. Set the
Velocity
parameter value to the value noted in step 6.