SuperTrak Conveyance Platform Overview
SuperTrak™ GEN3 System Operation and Maintenance Manual
31
Rev. 9 (12-2021)
Right Coil Driver Board
The left coil driver board and the right coil driver board are the same. The
connections to the gateway boards are different, so they are referenced
as the “left” or “right” coil driver board.
A
Right encoder cable
F
Ribbon cable connection - connects to
the bottom-right of the coil driver board
B
Thermistor connector (1 of 5)
G
24V digital power cable
(battery backup)
C
Coil connection
(1 of 5: two coils for each connection)
H
Gateway network cable
D
Motor power connection
a
a.The motor power connection is 28VDC between two (2) high power sections, and 15VDC between
two (2) low power sections. There is no motor power connection between a high power section and
a low power section.
I
Common connection
E
Ribbon cable connection - connects to
the top-right of the coil driver board
J
Frame ground connection