Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
153
Rev. 9 (12-2021)
6. Remove the fourteen (14) screws that
secure the board to the bus bar.
7. Disconnect the three (3) thermistor
connections.
Squeeze the tabs for each thermistor
connector plug and then pull straight out.
8. Lean the coil driver board forward and lift straight up.
Remove a Coil Driver Board - 180 Deg. Section (800 mm)
or 90 Deg. Section
1. Turn the
SuperTrak conveyance platform power disconnect switch
to
the OFF position.
2. Lock out and tag hazardous energy.
3. Use a flat head screwdriver to remove the screws from the electrical door, and
then set the electrical door aside.
4. Remove the gateway board.
Complete steps 4 to 9 of the
Remove a Gateway Board - Straight Section, 90
Deg. Section, or 180 Deg. (800 mm) Section
5. Remove the coil driver board.
Complete steps 4 to 7 of the
Remove a Coil Driver Board - Straight Section
To prevent electrical board damage from electrostatic discharge (ESD),
use an ESD wrist strap when working with the coil driver board. An ESD
wrist strap prevents the buildup of static electricity.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...