Technician Procedures
SuperTrak™ GEN3 System Operation and Maintenance Manual
217
Rev. 9 (12-2021)
Install a Pallet Setup Stationary Mount
1. Position a stationary mount on a straight section. Make sure the datum surface,
which is etched with the a “D”, faces toward the encoders. Roughly center the
stationary mount with an odd-numbered encoder.
In the example below, all odd-numbered encoders are circled. The stationary
mount is aligned with encoder 3 (the 4
th
encoder from the left).
2. Install shims between the encoder assembly and the stationary mount, to bias
the stationary mount to the back of the t-slot.
In the example on the right, a green and
white 0.729 mm (0.028 in.) shim is
installed on the left, and a white
0.653 mm (0.025 in.) shim is installed on
the right to bias the stationary mount to
the back.
3. Lower the shims all the way down.
4. Snug the two (2) stationary mount
screws.
Make sure the t-nuts turn and lock into
the t-slots.
5. Position an adjust block at the end of the
stationary mount, and secure it in position
with one (1) screw.
6. Repeat step 5 at the other end of the
stationary mount.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...