SuperTrak Conveyance Platform Overview
SuperTrak™ GEN3 System Operation and Maintenance Manual
29
Rev. 9 (12-2021)
Left Coil Driver Board with a Power Supply Connected
This drawing indicates the connections that are different on the left coil driver
board when a power supply is connected.
If the SuperTrak conveyance platform is programmed with more than one
safety circuit (different guard zones), remove the 28VDC motor power
connection from the zone boundaries.
See the
SuperTrak Conveyance Platform Electrical Drawings
for
additional information.
The left coil driver board and the right coil driver board are the same. The
connections to the gateway boards are different, so they are referenced
as the “left” or “right” coil driver board.
A
50A fuse
a
C
Motor power connection
b
b.The motor power connection is 28VDC between two (2) high power sections, and 15VDC between
two (2) low power sections. There is no motor power connection between a high power section and
a low power section.
B
Power supply connection:28VDC for
standard straight section, or 15VDC
for a low power straight section
D
Common connection
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...