7. Remove the chip finder from the left side of the stationary mount and turn it
180°.
8. Install the chip finder on the right side of the stationary mount:
a. Align the chip finder with the left
side of the stationary mount.
b. Loosely secure the chip finder in
position using the thumb screw.
c. Firmly hold the chip finder back
and to the left, and then tighten
the thumb screw.
9. For step 3 on the TrakMaster screen, click
Accept
.
10. View the value displayed in step 4 on the TrakMaster screen to determine the
direction and distance to adjust the pallet setup station locate.
For example; this screen indicates that the pallet setup station locate must be
adjusted to the left 158 microns.