186
SuperTrak™ GEN3 System Operation and Maintenance Manual
Rev. 9 (12-2021)
Technician Procedures
7. As applicable, connect the two (2) Ethernet cables (left and right network
cables) to the F-F coupler:
•
For the 180 deg. (500 mm)
section, connect the cables on the
right side (as indicated) of the F-F
coupler.
•
For the 180 deg. (800 mm)
section, connect the cables to the
left side (as indicated) of the F-F
coupler.
•
For the 90 deg. section, connect
the cables to the left side (as
indicated) of the
F-F coupler.
8. Install a ferrite onto the left network patch cable.
Make sure the ferrite is within 10 cm (4 in.) of the connector.