Troubleshooting
SuperTrak™ GEN3 System Operation and Maintenance Manual
259
Rev. 9 (12-2021)
Test Straight Section or Curved Section
Hardware
This section describes how to test the functionality of straight section or curved
section hardware components.
Test Encoder Functionality
1. Open TrakMaster.
2. In the left pane, click
Diagnostic
>
Encoders
.
3. If required, click the
Status
tab.
4. At the top of the screen, click
or
to select the required
Section
to test.
5. By hand, slowly move a pallet
across the section you selected in
step 4. As you move the pallet,
watch the grey Xs on the left side
of the screen. The Xs, beginning
with
Encoder
0 or 15 depending
on the direction the pallet is
moving, should change to a yellow
star and then to a green
checkmark. As the pallet continues
to travel across the section the
green checkmark may or may not
change back to a yellow star and then back to a grey X.
The encoders pass if all the grey Xs sequentially change to a green checkmark.
TrakMaster software is required for most of the straight section or curved
section hardware testing procedures.
Summary of Contents for SuperTrak GEN3
Page 1: ...Rev 9 December 2021...
Page 2: ......
Page 3: ...SuperTrak GEN3 Conveyance Platform Modular Conveyor Operation and Maintenance Manual...
Page 6: ......
Page 12: ...This page is intentionally blank...
Page 30: ...This page is intentionally blank...
Page 58: ...This page is intentionally blank...
Page 296: ...This page is intentionally blank...
Page 300: ...This page is intentionally blank...
Page 364: ...This page is intentionally blank...
Page 366: ...This page is intentionally blank...