Rostock MAX v2 Assembly Guide
completed. Change the value to 128 and click on the “Save To EEPROM” button and restart the auto
tune process once the hot end has cooled to room temperature.
Once the auto tune is completed, the values that you're interested in are the “Kp”, “Ki” and
“Kd” values. There are three blocks of these values, each under the heading “Classic PID”. Create an
average of all the values (add up all the Kp values, divide by three. Do the same with the Ki and Kd
values) and we'll get them added to the proper spot in the EEPROM table.
In order to store your new set of PID values, we need to open up the EEPROM table editor. The
EEPROM table editor is on the same screen as the terminal. Click on “EEProm Settings” box to open
the editor, just as you
did if you needed to
adjust the PID max
value.