14-319
14-319
14.5.1. Position (ABS)
Data concerning the position of each axis motor can be monitored.
The following data can be monitored.
-
Position feedback
Current motor rotation position is displayed by the pulse value of the encoder.
-
Position in 1 rotation
Present single motor rotation position of the encoder is displayed.
(It is not displayed in the CR800/750/700 series controller. It is always 0.)
-
Fdt command
The amount of the change of the position command between the control cycles is shown.
(It is not displayed in the CR800/750/700 series controller. It is always 0.)
-
Position droop
The amount of deflection at the motor rotation position relative to the position command is shown.
-
Max. position droop
The maximum value of position droop after robot controller’s power supply is turned on is displayed.
-
Position command
The command of the motor rotation position for the servo is displayed by the pulse value.
Click the [Reset] button to reset all Servo Monitors.
Figure 14-50 Servo monitor - ABS