27-633
27-633
Check item or cause
Solution
Is there a error occurred in the PLC CPU?
Extend the time of [(4)Check at Communication Time] on
the [Detail setting] screen of [CRnQ_R communication
setting].
What color is Communication Server 2?
Return Communication Server 2 to icon
status and check the color displays for the
line state.
Red
The problem may be that the robot
controller is not connected correctly.
Check the items in
Communication Server 2 is red
(overall)"
.
Green
The problem may be that the robot
controller and the computer have different
communications settings. Check the items
in
"(5) When Communication Server 2 is
.
Yellow
Check the items in
Communication Server 2 is yellow
(overall)"
.
Light blue Check the items in
Communication Server 2 is in light blue
or blue (overall)".
Blue
(4)
When Communication Server 2 is red (overall)
When Communication Server 2 is displayed in red, check the following.
Check item or cause
Solution
Is the communications cable connected
correctly?
Connect the cable correctly.
Are you using the correct communication
cable?
Check the communication cable specifications.
Be careful. RS-232 cables and Ethernet cables can be
either cross cables or straight cables.
For the cable specifications, check your robot's
"Standard Specifications".
When connected by CRnQ_R
communication, is the target CPU set
correctly?
Set the target CPU correctly.
For details, see
.
(5)
When Communication Server 2 is green (overall)
When Communication Server 2 is displayed in green, check the following.
Содержание 3F-14C-WINE
Страница 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Страница 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Страница 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Страница 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Страница 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Страница 624: ...24 624 24 624 Figure 24 4 Document output example ...