9.2.3. RS-232 Communication Settings
Change the RS-232 communication settings to match the robot controller side communications settings.
RS-232 communication can be used when connecting to a CR700 or CR500 series controller.
Figure 9-4 RS-232 Communication Settings
Table 9-4 RS-232 Communication Setting Items and Default Values
Item
Explanation
Default value
Port used
COM1 – COM10 can be selected.
COM1
Communication
speed
Select from 4800, 9600, and 19200.
+ It is possible to select Baud rate 38400 only when
connecting this software with the CRnD-700 controller.
9600
Character size
7 or 8 can be selected, but select 8.
8
Parity
None, Odd, or Even can be selected.
EVEN
Stop bit
Select from 1, 1.5, and 2.
2
Send timeout
Timeout time for sending
Settable range
Minimum value
: 1000 msec
Maximum value
: 30000 msec
5000 msec
Receive timeout
Timeout time for receiving
Settable range
Minimum value
: 5000 msec
Maximum value
: 120000 msec
30000 msec
Retries
Number of communication retries
Settable range
Minimum value
: 0
Maximum value
: 10
3
Usage protocol
Non-Procedural or Procedural can be selected.
Procedural
Set the following to perform a high-speed, stable communication.
Baud rate
: 19200 bps
Protocol used
: Procedural
It is also necessary to change the communication settings to the same value of the robot controllers at this
time.
Normal operation not guaranteed with USB to RS-232 cables.
Normal operation is not guaranteed when using the USB to RS-232 cable. When using the RS-232
as a communication port, use of a computer with a serial port is recommended.
Caution
Содержание 3F-14C-WINE
Страница 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Страница 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Страница 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Страница 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Страница 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Страница 624: ...24 624 24 624 Figure 24 4 Document output example ...