14-308
14-308
14.3.3. Stop signal
You can reference the statuses of stop signals (stop/not stop) input to the robot controller.
From the project tree, double-click the target project [Online] -> [Monitor] -> [Signal Monitor] -> [Stop Signals].
Figure 14-36 Stop Signal (Connected with CR800 series controller)
Figure 14-37 Stop Signal (Connected with CR750/700/500 series controller)
Stop
O/P
Operation panel
T/B
Teaching box
I/O
Dedicated input signal STOP and STOP 2, stop dedicated input
(
SKIP
input
)
PC
Stop by communication from PC etc.
Emergency
stop
O/P
Operation panel
T/B
Teaching box
I/O
External emergency stop input
(
CNUSR connector, EMGIN connector
)
EMG1/EMG2
Input state of external emergency stop (EXTEMG11/EXTEMG12)
DOOR1/DOOR2
State of door switch connection
(
DOOR1/DOOR2
)
OPKEY1/OPKEY2
The state input of Mode selector switch
(
OPKEY1/OPKEY2
)
TBEMG1/TBEMG2 Input state of the emergency stop button switch of the teaching box
TBENA1/TBENA2
Teaching box operation enable switch input state
(
TB ENABLS
)
DM1/DM2
Input state of the enable switch of the teaching box(3 position switch)
Pin name of CNUSR 11 connector of controller
Содержание 3F-14C-WINE
Страница 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Страница 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Страница 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Страница 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Страница 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Страница 624: ...24 624 24 624 Figure 24 4 Document output example ...