15-340
15-340
Table 15-4 Description of the Setup Screen
Item
Explanation
Factory
preset
value
(1)
Maintenance Forecast is
made effective.
If this is checked, the Maintenance Forecast function is enabled.
* If the checkmark is removed, the collection of Maintenance Forecast
information stops, and the correct maintenance times cannot be
calculated.
Check
ON
(2)
Collection level of information
Five levels can be specified to collect the information on maintenance.
* As the information collection level gets higher, the accuracy of the
maintenance improves, but it affects the tact time more.
1
(Recomm
ended)
(3)
The interval of the forecast
Specify the interval of maintenance time notification.
6 hours
How to inform
When the grease replenishment, belt replacement, and other maintenance times
have been reached, they can be notified by generating a warning or outputting a
dedicated signal. As for the battery replacement time, one of warnings, C7500,
C7510, and C7520, is generated, regardless of whether or not [Warning] under
[How to inform] is checked.
The warning generated varies depending on each situation.
(4)
Warning
If this item is checked, the maintenance time is notified as a warning.
The warning numbers are listed as follows:
Grease : C753* (* is the axis No.)
Belt : C754* (* is the axis No.)
Check
ON
(5)
Output Signal
If this item is checked, signal numbers can be entered. If this item is
checked and a signal number is entered correctly, the maintenance
time is notified using the output of the designated signal.
Check
OFF
(6)
Assumption operation
time of a day
Enter an estimated robot operation hours per day.
16 hours
(7)
The remainder days until
presumed maintenance
time
Specify the number of days remaining until estimated maintenance
time for use as a reference to notify the maintenance time.
14 days
How to reset the generated warning and output warning signal
There are output of warning occurrence (C753 *, C754 * (* is the axis number)) and dedicated output
signal (M * PTEXC (* is the robot number)) as a notification method of each part replacement time.
When both are set by the notification method, it is possible to turn off the warning occurrence and turn off
the signal output by the error reset operation.
If you wish to invalidate "warning occurrence" and make only the output of the dedicated output signal
valid with the notification method, even if you press the reset button on the front of the controller, the output
signal will not turn OFF. In this case, if you press the [ERROR RESET] key of the teaching pendant or input
the error reset signal (ERRRESET), the signal output turns OFF.
Notification method
setting
Notification
method
How to reset notification (warning occurrence or dedicated
signal output)
Warnings
Dedicated
Output
Signal
On the front of the
controller
[RESET]
T / B's
[ERROR RESET]
From the outside
Error reset signal
Warning
occurrence
Possible
Possible
Possible
Warning
occurrence
Dedicated
signal output
Warning,
dedicated signal
Resetable
Warning,
dedicated signal
Resetable
Warning,
dedicated signal
Resetable
Dedicated signal
output
Can not reset
Possible
Possible
MEMO
Содержание 3F-14C-WINE
Страница 84: ...8 84 8 84 Figure 8 21 Parameter transfer procedure 1 2 2 ...
Страница 393: ...18 393 18 393 Figure 18 1 Starting the Oscillograph ...
Страница 413: ...18 413 18 413 Figure 18 24 Output to Robot program Selection ...
Страница 464: ...18 464 18 464 Figure 18 72 Starting the Tool automatic calculation ...
Страница 545: ...21 545 21 545 Figure 21 55 Hide display of user mechanism ...
Страница 624: ...24 624 24 624 Figure 24 4 Document output example ...