![Dräger Infinity Acute Care System M540 Скачать руководство пользователя страница 422](http://html.mh-extra.com/html/drager/infinity-acute-care-system-m540/infinity-acute-care-system-m540_instructions-for-use-manual_2526773422.webp)
External devices – Servo-i ventilator
422
Instructions for use – Infinity Acute Care System – Monitoring Applications VG6.n
Supported Servo-i parameters
The following table lists which Servo-i ventilator pa-
rameters are displayed and trended on the Cockpit.
Refer to page 421 for a list of supported ventilators
and the compatible software versions.
Parameter
label
Description
Unit of
mea-
sure-
ment
Displayed in Ventila-
tion
Show all
page
(see page 426)
Yes/No?
Cockpit
Trends
page
Available
for display
in parame-
ter field
Yes/No?
Cdyn
Dynamic compliance L/bar
Yes
Continuous
No
etCO2
End-tidal CO2
concentration
mmHg
Not supported for
display
Continuous and
mini-trend
Yes
kPa
%
FiO2
Inspired O2
%
Yes
Continuous
No
MVe
Minute volume,
expired
L/min
Yes
Continuous and
mini-trend
Yes
MVespon
Spontaneous
expiratory minute
volume
L/min
Yes
Continuous
No
PEEP
Peak end expiratory
airway pressure
cmH2O
Yes
Continuous
Yes
PIP
Peak inspiratory
pressure
cmH2O
Yes
Continuous and
mini-trend
Yes
Pmean
Mean airway
pressure
cmH2O
Yes
Continuous
Yes
RR
Respiratory rate
/min
Yes
Continuous
Yes
V'CO
2
Carbon dioxide
production
mL/min
Yes
Continuous
No
VTe
Tidal volume,
expired
mL
Yes
Continuous
Yes