Phadia 100 - User Manual
Printouts
12-3501-20/12
Page 10.5
10
Distribution List
This printout lists the components and where they are placed in the instrument.
To print this list select
1.2.Print Lists, DISTR
option on the instrument.
Type of sample allocated to this
position:
Sample
Unknown
sample
Cal
Calibrator
Curve control
Curve control
Quality control Quality control
sample
Empty
Empty tube
(for dilution)
Diluent
Diluent
solution
Position in Sample Carousel
Component allocated to this po-
sition, listed by method and iden-
tity (unknown listed by identity
only)
Position in ImmunoCAP Carousel
ImmunoCAP allocated to the po-
sition, listed by method and test
Position in Sample Carousel from
which sample will be dispensed
into the ImmunoCAP position
Calibration Code of conjugate
Identity of component to dis-
pense into the ImmunoCAP posi-
tion
In case of dilution, the dilution
method is printed here.
The dilution method could be:
Instr
Instrument dilution
Pre
Prediluted
If methods use calibration codes
on ImmunoCAP, these will be
printed here
Method version number
Dilution factor for prediluted
sample
Dilution factor for instrument di-
luted sample
Dilution factors for sample
Run sequence number
Date and time of the first entered
request
Instrument serial number
Software version number
Date and time of printout
Lot number for QC
DISTRIBUTION LIST
Run number:
1
Run created: 090508 16:15
Run origin:
Instrument
SAMPLE CAROUSEL
A sIgE
Conjugate
1P
B tIgE
Conjugate
3C
E
Development solution
H
Stop solution
01 S01
Sample
Pre 20
02 S02
Sample
03 S02
Empty
Instr 10
04 sIgE CAL-0.35
Cal
05 sIgE CAL-0.70
Cal
06 sIgE CAL-3.50
Cal
07 sIgE CAL-17.5
Cal
08 sIgE CAL-50.0
Cal
09 sIgE CAL-100
Cal
10 tIgE CC-1
Curve control
11 tIgE CC-2
Curve control
12 sIgE QC-2
Quality controlAVMAB
13 tIgE QC-1
Quality controlAWNA9
14
Diluent
ImmunoCAP CAROUSEL
01 sIgE a_IgE <- 04 CAL-0.35
02 sIgE a_IgE <- 04 CAL-0.35
03 sIgE a_IgE <- 05 CAL-0.70
04 sIgE a_IgE <- 05 CAL-0.70
05 sIgE a_IgE <- 06 CAL-3.50
06 sIgE a_IgE <- 06 CAL-3.50
07 sIgE a_IgE <- 07 CAL-17.5
08 sIgE a_IgE <- 07 CAL-17.5
09 sIgE a_IgE <- 08 CAL-50.0
10 sIgE a_IgE <- 08 CAL-50.0
11 sIgE a_IgE <- 09 CAL-100
12 sIgE a_IgE <- 09 CAL-100
13 tIgE a-IgE <- 10 CC-1
3C
14 tIgE a-IgE <- 11 CC-2
3C
15 sIgE e1 <- 12 QC-2
16 tIgE a-IgE <- 13 QC-1
17 tIgE a-IgE <- 01 S01
20
18 tIgE a-IgE <- 01 S02
100
0354, 090508 16:22, 2.3, 032
Run origin:
Instrument The run was created
in the instrument
PC Remote
The run was created
on a PC using IDM
Summary of Contents for Phadia 100
Page 1: ...Phadia 100 English 12 3501 20 12 User Manual...
Page 81: ...Routine Assay Run Phadia 100 User Manual Page 2 50 12 3501 20 12...
Page 91: ...Reagent and Sample Handling Phadia 100 User Manual Page 3 10 12 3501 20 12...
Page 251: ...Printouts Phadia 100 User Manual Page 10 22 12 3501 20 12...
Page 277: ...Maintenance Phadia 100 User Manual Page 11 26 12 3501 20 12...
Page 341: ...Error Handling Phadia 100 User Manual Page 12 64 12 3501 20 12...
Page 348: ...Phadia 100 User Manual Index 12 3501 20 12 Page 15 1 15 Chapter 15 Index...