![Texas Instruments AM1808 Technical Reference Manual Download Page 354](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558354.webp)
Registers
354
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Programmable Real-Time Unit Subsystem (PRUSS)
Table 13-39. CONTABBLKIDX0 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-20
RESERVED
R
0
19-16
C25
R/W
0
PRU Constant Entry 25 Block Index: This field sets the value that will appear
in bits 11:8 of entry 25 in the PRU Constant Table
15-4
RESERVED
R
0
3-0
C24
R/W
0
PRU Constant Entry 24 Block Index: This field sets the value that will appear
in bits 11:8 of entry 24 in the PRU Constant Table
13.8.1.3.7 CONTABPROPTR0 Register (Offset = 28h)
This register allows the PRU to set up the 256-byte page index for entries 28 and 29 in the PRU Constant
Table which serve as general purpose pointers which can be configured to point to any locations inside
the session router address map. This register is useful when the PRU needs to frequently access certain
structures inside the session router address space whose locations are not hard coded such as tables in
scratchpad memory. This register is formatted as follows:
Figure 13-30. CONTABPROPTR0 Register
31
16 15
0
C29
C28
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 13-40. CONTABPROPTR0 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
C29
R/W
0
PRU Constant Entry 29 Pointer: This field sets the value that will appear in
bits 23:8 of entry 29 in the PRU Constant Table
15-0
C28
R/W
0
PRU Constant Entry 28 Pointer: This field sets the value that will appear in
bits 23:8 of entry 28 in the PRU Constant Table
13.8.1.3.8 CONTABPROPTR1 Register (Offset = 2Ch)
This register functions the same as the PRU Constant Table Programmable Pointer Register 0 but allows
the PRU to control entries 30 and 31 in the PRU Constant Table. This register is formatted as follows:
Figure 13-31. CONTABPROPTR1 Register
31
16 15
0
C31
C30
R/W-0
R/W-0
LEGEND: R/W = Read/Write; R = Read only; -n = value after reset
Table 13-41. CONTABPROPTR1 Register Field Descriptions
Bit
Field
Type
Reset
Description
31-16
C31
R/W
0
PRU Constant Entry 31 Pointer: This field sets the value that will appear in
bits 23:8 of entry 31 in the PRU Constant Table
15-0
C30
R/W
0
PRU Constant Entry 30 Pointer: This field sets the value that will appear in
bits 23:8 of entry 30 in the PRU Constant Table