![Texas Instruments AM1808 Technical Reference Manual Download Page 217](http://html.mh-extra.com/html/texas-instruments/am1808/am1808_technical-reference-manual_1094558217.webp)
SYSCFG Registers
217
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
System Configuration (SYSCFG) Module
10.5.8.2 Fault Status Register (FLTSTAT)
The fault status register (FLTSTAT) holds/captures additional attributes and status of the first erroneous
transaction. This includes things like the master id for the master that caused the address/memory
violation error, details on whether it is a user or supervisor level read/write or execute fault. The FLTSTAT
is shown in
and described in
Figure 10-14. Fault Status Register (FLTSTAT)
31
24
23
16
ID
MSTID
R-0
R-0
15
13
12
9
8
6
5
0
Reserved
PRIVID
Reserved
TYPE
R-0
R-0
R-0
R-0
LEGEND: R = Read only; -
n
= value after reset
Table 10-18. Fault Status Register (FLTSTAT) Field Descriptions
Bit
Field
Value
Description
31-24
ID
0-FFh
Transfer ID of the first fault transfer.
23-16
MSTID
0-FFh
Master ID of the first fault transfer.
15-13
Reserved
0
Reserved. Always read 0
12-9
PRIVID
0-Fh
Privilege ID of the first fault transfer.
8-6
Reserved
0
Reserved. Always read 0
5-0
TYPE
Fault type of first fault transfer.
0
No transfer fault
1h
User execute fault
2h
User write fault
3h
Reserved
4h
User read fault
5h-7h
Reserved
8h
Supervisor execute fault
9h-Fh
Reserved
10h
Supervisor write fault
11h-1Fh
Reserved
20h
Supervisor read fault
21h-3Fh
Reserved