Instruction Formats
324
SPRUH82C – April 2013 – Revised September 2016
Copyright © 2013–2016, Texas Instruments Incorporated
Programmable Real-Time Unit Subsystem (PRUSS)
Table 13-7. Format 1a: (All Arithmetic and Logical Functions – Register Op2) (continued)
Bit
Field
Description
7-5
RdSel
0 = Select bits 7:0 of the destination register
1 = Select bits 15:8 of the destination register
2 = Select bits 23:16 of the destination register
3 = Select bits 31:24 of the destination register
4 = Select bits 15:0 of the destination register
5 = Select bits 23:8 of the destination register
6 = Select bits 31:16 of the destination register
7 = Select bits 31:0 of the destination register
4-0
Rd
0-31 = This field selects the destination register number to which the result should be written.