Setting digital inputs
1. Select "Parameters" and "Inputs" in the navigation.
Figure 6-13
Digital inputs
2. Select the appropriate input signal in the table for the measuring inputs and the temperature
control:
– "Digital input 0 (X130/DI 0)": Probe 1
– "Digital input 1 (X130/DI 1)": Probe 2
– "Digital input 2, 3 (X130/DI 2+, DI 2-, DI 3+, DI 3-)":
Fail-safe digital input for the Safety Integrated Basic Function "STO" or "SS1".
The configuration is performed via the Safety commissioning. By clicking "Safety", you
open the Safety commissioning and can make the appropriate settings there.
"Safety commissioning (Page 135)"
– "Digital input 4 (X130/DI 4)": Temperature monitoring of ext. braking resistor
3. Click
to save the data permanently.
Commissioning and diagnostics in the Web server
6.6 Settings
SINAMICS S210 servo drive system