Procedure
1. Select "System" and "Settings" in the navigation.
2. Select the "IP Connections and Addresses" tab.
Figure 6-35
IP connections
3. Activate the desired connection options.
4. Click "Apply Settings" to save the changes in the RAM of the device.
5. Click
to save the data permanently.
Note
Switchover from HTTP to HTTPS
If you were logged-in via HTTP, then after activating option "Only use HTTPS connection",
you will be logged-out. To log in again, you must set a secure HTTPS connection (https://...)
to the converter.
Commissioning and diagnostics in the Web server
6.11 System settings
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
159