![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 285](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045285.webp)
09
SDI negative selected
Yes
No
-
12
Test stop active
Yes
No
-
13
Test stop required
Yes
No
-
r9765
SI Motion forced checking procedure remaining time
Data type: FloatingPoint32
P group: Safety Integrated
Description:
Displays the time remaining until the next dynamization and testing of the safety motion monitoring functions integrated
in the drives.
The signal source to initiate the forced checking procedure is parameterized in p9705.
Dependency:
See also: C01798
r9767
SI safety password status
Data type: Unsigned32
P group: Safety Integrated
Description:
Display and binector output for the status of the safety password.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Assign password
Yes
No
-
01
Password entered
Yes
No
-
Note
For bit 00 = 1:
- a valid safety password was assigned.
For bit 01 = 1:
- a valid safety password was assigned (bit 0 = 1).
- safety parameters can be set.
r9768[0...7]
Receive SI PROFIsafe control words
Data type: Unsigned16
P group: Safety Integrated
Description:
Displays the received PROFIsafe telegram from the control.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Dependency:
See also: r9769
Note
The PROFIsafe trailer at the end of the telegram is also displayed (2 words).
r9769[0...7]
Send SI PROFIsafe status words
Data type: Unsigned16
P group: Safety Integrated
Description:
Displays the PROFIsafe telegram to be sent to the control.
Index:
[0] = PZD 1
[1] = PZD 2
[2] = PZD 3
[3] = PZD 4
[4] = PZD 5
[5] = PZD 6
[6] = PZD 7
[7] = PZD 8
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA