![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 88](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045088.webp)
5.2.3
Fitting output elements
NOTICE
Damage to the motor due to runout on the shaft extension
Runout and thrust on the shaft extension of the motor can damage the motor.
● Mount the motor without runout and thrust on the shaft extension.
Mount or remove the power output elements (e.g. couplings, gear wheels, belt pulleys) using
suitable devices only (see figure).
● Use the threaded hole in the shaft extension.
● If required, heat up the output elements before mounting or removing.
● When removing the output elements, use an intermediate disk to protect the centering in
the shaft extension.
● If necessary, completely balance the motor together with the output elements according to
ISO 1940.
Note
Motors with feather key are half-key balanced. The motors have been balanced with half
a feather key.
1
Intermediate washer/disk (to protect the centering in the shaft extension)
Figure 5-1
Mounting and removing output elements
The motor dimensions can be found in Chapter:
"Dimension drawings of motor (Page 207)"
Installing
5.2 Installing the motor
SINAMICS S210 servo drive system
86
Operating Instructions, 12/2017, A5E41702836B AA
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Page 767: ......