![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 280](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045280.webp)
Note
For index [0]:
The display of the load-side position actual value on the first channel is updated in the monitoring clock cycle.
For index [1]:
The display of the load-side position actual value on the second channel is updated in the KDV clock cycle (r9724)
and delayed by one KDV clock cycle.
For index [2]:
The difference between the load-side position actual value in the first channel and load-side position actual value in
the second channel is updated in the KDV clock cycle (r9724) and delayed by one KDV clock cycle.
For index [3]:
The maximum difference between the load-side position actual value in the first channel and the load-side position
actual value in the second channel.
KDV: Data cross-check
r9710[0...1]
SI Motion diagnostics result list 1
Data type: Unsigned32
P group: Safety Integrated
Description:
Displays result list 1 that, for the data cross-check between the monitoring channels, led to the fault.
Index:
[0] = Result list channel 2
[1] = Result list channel 1
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Actual value > upper limit SOS
Yes
No
-
01
Actual value > lower limit SOS
Yes
No
-
06
Actual value > upper limit SLS1
Yes
No
-
07
Actual value > lower limit SLS1
Yes
No
-
08
Actual value > upper limit SLS2
Yes
No
-
09
Actual value > lower limit SLS2
Yes
No
-
10
Actual value > upper limit SLS3
Yes
No
-
11
Actual value > lower limit SLS3
Yes
No
-
12
Actual value > upper limit SLS4
Yes
No
-
13
Actual value > lower limit SLS4
Yes
No
-
16
Actual value > upper limit SAM/SBR
Yes
No
-
17
Actual value > lower limit SAM/SBR
Yes
No
-
18
Actual value > upper limit SDI positive
Yes
No
-
19
Actual value > lower limit SDI positive
Yes
No
-
20
Actual value > upper limit SDI negative
Yes
No
-
21
Actual value > lower limit SDI negative
Yes
No
-
Dependency:
See also: C01711
Note
SBR: Safe Brake Ramp (safe brake ramp monitoring)
SDI: Safe Direction (safe motion direction)
SLS: Safely Limited Speed
SOS: Safe Operating Stop
r9711[0...1]
SI Motion diagnostics result list 2
Data type: Unsigned32
P group: Safety Integrated
Description:
Displays result list 2 that, for the data cross-check between the monitoring channels, led to the fault.
Index:
[0] = Result list channel 2
[1] = Result list channel 1
Bit field:
Bit
Signal name
1 signal
0 signal
FP
16
Actual value > upper limit SSM+
Yes
No
-
17
Actual value > lower limit SSM+
Yes
No
-
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
278