![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 322](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045322.webp)
Cause:
The component number from the topology was not parameterized (p0121 (for power unit, refer to p0107), p0131 (for servo/
vector drives, refer to p0107), p0141, p0151, p0161).
Fault value (r0949, interpret decimal):
Data set number.
Note:
The fault also occurs if encoders have been configured (p0187 to p0189) but no component numbers exist for them.
In this case, the fault value includes the drive data set number plus 100 * encoder number (e.g. 3xx, if a component number
was not entered in p0141 for encoder 3 (p0189)).
Remedy:
- enter missing component number.
- if required, remove the component and restart commissioning.
A01306
Firmware of the DRIVE-CLiQ component being updated
Message value:
%1
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
Firmware update is active for at least one DRIVE-CLiQ component.
Alarm value (r2124, interpret decimal):
Component number of the DRIVE-CLiQ component.
Remedy:
Not necessary.
This alarm is automatically withdrawn after the firmware update has been completed.
A01314
Topology: Component must not be present
Message value:
%1, to %2, %3, connection: %4
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
For a component, "deactivate and not present" is set but this component is still in the topology.
Alarm value (r2124, interpret hexadecimal):
ddccbbaa hex:
aa = component number
bb = component class of the component
cc = connection number
Note:
Component class and connection number are described in F01375.
Remedy:
- remove the corresponding component.
- change the setting "deactivate and not present".
Note:
Under "Topology --> Topology view", the commissioning tool where relevant offers improved diagnostics capability (e.g.
setpoint/actual value comparison).
A01317 (N)
Deactivated component again present
Message value:
-
Drive object:
All objects
Reaction:
NONE
Acknowledge:
NONE
Cause:
If a component of the target topology for an active drive object is inserted and the associated parameter of the component
is set to "deactivate" (p0125, p0145, p0155, p0165).
Note:
This is the only message that is displayed for a deactivated component.