8.2.1
Electromagnetic compatibility
Converters are equipment used on a professional basis, deployed in certain areas of business
and industry – and are not operated in the general public domain.
For an EMC-compliant installation, observe the information provided in the Configuration
Manual: EMC installation guideline (
http://support.automation.siemens.com/WW/view/en/
).
The devices described there are intended for operation in the first and second environments.
The drive system must be installed by appropriately qualified personnel in compliance with
EMC regulations - and the installation notes provided in the manual.
Electromagnetic compatibility according to EN61800-3
Property
Version
Interference immunity The converters are suitable for use in the first and second environments without restrictions
Interference emission
- second environment
Category C2 Up to a motor cable length of 10 m
1)
Up to a motor cable length of 25 m with additional external line filter
Category C3 Up to a motor cable length of 25 m
Up to a motor cable length of 50 m with additional external line filter
1)
Converters of frame size FSB require a ferrite core for the motor cable to reach category C2.
Connecting the converter (Page 93).
Note
Installation in Category C2 environments
Converters that are installed in environments of category C2 require a connection approval for
the low-voltage supply system. In this regard, contact your power system operator.