![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 91](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045091.webp)
5.4
Connecting the converter and the motor
5.4.1
Cable lengths
Permissible cable lengths for the connection of the motor to the converter.
Converter without additional line
filter
Converter with additional exter‐
nal filter
EMC category C2
10 m
25 m
EMC category C3
25 m
50 m
External line filter (Page 219)
Connection cables between the motor and the converter (Page 217)
Electromagnetic compatibility (Page 199)
Permissible cable lengths for the other converter connections
Type of connection
Connection via
Permissible
cable length
Control voltage 24 VDC
X124
30 m
External braking resistor
X1 (R1, DCP)
3 m
Motor power connections
X2
50 m
Service interface
X127
10 m
Digital inputs
X130
30 m
Connection to the control system via PROFINET
X150 P1
X150 P2
100 m
Encoder
X100
50 m
Motor holding brake
X107
50 m
Installing
5.4 Connecting the converter and the motor
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
89
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Page 767: ......