![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 584](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045584.webp)
F31501 (N, A) Encoder 1: Position tracking encoder position outside tolerance window
Message value:
%1
Drive object:
All objects
Reaction:
Servo: OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
When switched off, the drive/encoder was moved through a distance greater than was parameterized in the tolerance
window. It is possible that there is no longer any reference between the mechanical system and encoder.
Fault value (r0949, interpret decimal):
Deviation (difference) to the last encoder position in increments of the absolute value.
The sign designates the traversing direction.
Note:
The deviation (difference) found is also displayed in r0477.
Remedy:
Reset the position tracking as follows:
- select encoder commissioning (p0010 = 4).
- reset the position tracking as follows (p0411.2 = 1).
- deselect encoder commissioning (p0010 = 0).
The fault should then be acknowledged and, if necessary, the absolute encoder adjusted (p2507).
See also: p0010
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
F31502 (N, A) Encoder 1: Encoder with measuring gear without valid signals
Message value:
-
Drive object:
All objects
Reaction:
Servo: OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The encoder with measuring gear no longer provides any valid signals.
Remedy:
It must be ensured that all of the encoders, with mounted measuring gear, provide valid actual values in operation.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Acknowl. upon A: NONE
F31503 (N, A) Encoder 1: Position tracking cannot be reset
Message value:
-
Drive object:
All objects
Reaction:
Servo: OFF1 (NONE, OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
The position tracking for the measuring gear cannot be reset.
Remedy:
The fault should be resolved as follows:
- select encoder commissioning (p0010 = 4).
- reset the position tracking as follows (p0411.2 = 1).
- deselect encoder commissioning (p0010 = 0).
The fault should then be acknowledged and the absolute encoder adjusted.
Reaction upon N: NONE
Acknowl. upon N: NONE
Reaction upon A: NONE
Faults and alarms