8.3
Technical data and properties of the connection system
MOTION-CONNECT connection cables between the motor and the converter
The following technical data applies to the MOTION-CONNECT OCC cables.
Table 8-9
MOTION-CONNECT OCC cable with SPEED-CONNECT connector
Designation and use
Cable type
Connector
size
Outer diame‐
ter
Minimum
bending ra‐
dius, static
For con‐
nection to
motor
Article number
1)
D
max
/ mm
R
/ mm
Motor connection cable
MC500 OCC for predom‐
inantly fixed installation
M12
9.7
23.5
1FK2☐02
1FK2☐03
6FX5002-8QN04-
☐☐☐☐
M17
10.5
25.5
1FK2☐04
6FX5002-8QN08-
☐☐☐☐
Motor connection cable
MC800 OCC for use in a
cable carrier
M12
9.7
28.2
1FK2☐02
1FK2☐03
6FX8002-8QN04-
☐☐☐☐
M17
10.5
30.6
1FK2☐04
6FX8002-8QN08-
☐☐☐☐
Extension cable
MC500 OCC for predom‐
inantly fixed installation
M12
9.7
23.5
1FK2☐02
1FK2☐03
6FX5002-8QE04-
☐☐☐☐
M17
10.5
25.5
1FK2☐04
6FX5002-8QE08-
☐☐☐☐
Extension cable
MC800 OCC for use in a
cable carrier
M12
9.7
28.2
1FK2☐02
1FK2☐03
6FX8002-8QE04-
☐☐☐☐
M17
10.5
30.6
1FK2☐04
6FX8002-8QE08-
☐☐☐☐
1)
The last 4 positions (☐☐☐☐) define the cable length corresponding to the length code.
The length code can be found in Chapter:
Connection cables between the motor and the converter (Page 217)
Technical data and notes for cable carrier use with MC800 PLUS
Note
You require an MC800 PLUS cable to connect the motor using a cable carrier.
Technical specifications
8.3 Technical data and properties of the connection system
SINAMICS S210 servo drive system
204
Operating Instructions, 12/2017, A5E41702836B AA