Index:
[0] = Gearbox 1
[1...7] = Reserved
Dependency:
See also: p9521
p9523
SI Motion redundant coarse position value valid bits
Changeable: C2(95)
Data type: Unsigned16
P group: Safety Integrated
Min: 0
Max: 16
Def: 9
Description:
Sets the number of valid bits of the redundant coarse position value.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Note
After starting the SI Motion copy function, this parameter is set after the encoder.
p9524
SI Motion Redundant coarse position value fine resolution bits
Changeable: C2(95)
Data type: Integer16
P group: Safety Integrated
Min: -16
Max: 16
Def: -2
Description:
Sets the number of valid bits for the fine resolution of the redundant coarse position value.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Note
After starting the SI Motion copy function, this parameter is set after the encoder.
p9525
SI Motion Redundant coarse position value relevant bits
Changeable: C2(95)
Data type: Unsigned16
P group: Safety Integrated
Min: 0
Max: 16
Def: 16
Description:
Sets the number of relevant bits for the redundant coarse position value.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Note
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9525 is automatically set when the system powers up.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9525 is checked to see that it matches the encoder.
p9529
SI Motion Gx_XIST1 coarse position safe most significant bit
Changeable: C2(95)
Data type: Unsigned16
P group: Safety Integrated
Min: 0
Max: 31
Def: 14
Description:
Sets the bit number for the safe most significant bit (MSB) of the Gx_XIST1 coarse position.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Note
MSB: Most Significant Bit
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9529 is automatically set when the system powers up.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9529 is checked to see that it matches the encoder.
p9530
SI Motion standstill tolerance
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.000 [mm]
Max: 100.000 [mm]
Def: 1.000 [mm]
Description:
Sets the tolerance for the "SOS" function.