Routing converter cables inside and outside a control cabinet
0RXQWLQJSODWH
6KLHOGVXSSRUW
)XVHVVZLWFKHVDQG
FRQWDFWRUV
)LOWHURSWLRQDO
&RQYHUWHU
&RQQHFWVKLHOG
(OHFWULFDOO\
FRQGXFWLYH
FRQQHFWLRQV
WKURXJKDODUJH
VXUIDFHDUHD
%UDNLQJUHVLVWRU
RSWLRQDO
&RQWUROFDELQHW
/LQH
&RQQHFWVKLHOG
&RQQHFWVKLHOG
Figure 3-1
Routing converter cables inside and outside a control cabinet
Routing cables outside the control cabinet
● Maintain a minimum clearance of 25 cm between cables with a high level of interference
and cables with a low level of interference.
● Use shielded cables for the following connections:
– Converter motor cable
– Cable between the converter and braking resistor
– Signal and data cables
Configuring
3.1 EMC-compliant installation of a machine or system
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
37