01
Position actual value sign change
Yes
No
-
04
No STOP A after encoder fault for 1 encoder safety
Yes
No
-
Dependency:
See also: F01671
p9518
SI Motion encoder pulses per revolution
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: 0
Max: 16777215
Def: 2048
Description:
Sets the number of encoder pulses per revolution.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Dependency:
See also: F01671
Note
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9518 is automatically set when the system powers up.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9518 is checked to see that it matches the encoder.
p9519
SI Motion fine resolution G1_XIST1
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: 2
Max: 18
Def: 11
Description:
Sets the fine resolution for G1_XIST1 in bits.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Dependency:
See also: F01671
Note
G1_XIST1: encoder 1 position actual value 1 (PROFIdrive)
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9519 is automatically set when the system powers up.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9519 is checked to see that it matches the encoder.
p9520
SI Motion spindle pitch
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.1000 [mm]
Max: 8388.0000 [mm]
Def: 10.0000 [mm]
Description:
Sets the gear ratio between the encoder and load in mm/revolution for a linear axis with rotary encoder.
NOTICE
The fourth decimal point can be rounded-off depending on the size of the entered number (from 3 places before the
decimal point).
p9521[0...7]
SI Motion gearbox encoder (motor)/load denominator
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: 1
Max: 2147000000
Def: 1
Description:
Sets the denominator for the gearbox between the encoder and load.
Index:
[0] = Gearbox 1
[1...7] = Reserved
Dependency:
See also: p9522
p9522[0...7]
SI Motion gearbox encoder (motor)/load numerator
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: 1
Max: 2147000000
Def: 1
Description:
Sets the numerator for the gearbox between the encoder and load.
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
265
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...