Cause:
There is a DRIVE-CLiQ communication error between the Control Unit and the HF Damping Module. The nodes do not
send and receive in synchronism.
Fault cause:
33 (= 21 hex):
The cyclic telegram has not been received.
34 (= 22 hex):
Timeout in the telegram receive list.
64 (= 40 hex):
Timeout in the telegram send list.
Note regarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
0000yyxx hex: yy = component number, xx = error cause
Remedy:
- carry out a POWER ON.
- replace the component involved.
Note:
HF Damping Module
F37836
HF Damping Module: Send error for DRIVE-CLiQ data
Message value:
Component number: %1, fault cause: %2
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Cause:
There is a DRIVE-CLiQ communication error between the Control Unit and the HF Damping Module. Data were not able
to be sent.
Fault cause:
65 (= 41 hex):
Telegram type does not match send list.
Note regarding the message value:
The individual information is coded as follows in the message value (r0949/r2124):
0000yyxx hex: yy = component number, xx = error cause
Remedy:
Carry out a POWER ON.
Note:
HF Damping Module
F37837
HF Damping Module: Component faulted
Message value:
Component number: %1, fault cause: %2
Drive object:
All objects
Reaction:
NONE
Acknowledge:
IMMEDIATELY
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
719
Summary of Contents for SIMOTICS S-1FK2