5.4.3.3
Connections for open-loop and closed-loop control of the converter
Connecting service interface and PROFINET
Connect your commissioning device using an Ethernet cable to
the service interface (socket X127).
The transmission rates are 10 Mbit/s or 100 Mbit/s.
Connect the converter with PROFINET cables with RJ45 FastConnect connectors or with
PROFINET patch cables (see accessories) via the sockets X150 P1 and X150 P2 to the
PROFINET network.
Table 5-3
Pin assignment for X127, X150 P1 and X150 P2
Pin
Pin assignment
Explanation
1
RXP
Receiving data +
2
RXN
Receiving data -
3
TXP
Sending data +
4
Reserved
5
Reserved
6
TXN
Sending data -
7
Reserved
8
Reserved
Connecting an external braking resistor
If you are using the internal braking resistor, DCP and R2 must be jumpered.
If you are using an external braking resistor, DCP and R2 must not be jumpered. Connect the
external braking resistor via the DCP and R1 terminals.
6KLHOG
'&3
5
5
'&3
5
5
①
Jumper when you use the internal braking resistor.
The jumper is included in the scope of delivery of the converter
②
Connect an external braking resistor
Protective conductor connection and shield support via the shield plate
Figure 5-16
X1 - connecting an external braking resistor
The terminals are spring-loaded terminals.
Permissible conductor cross-sections for single-core connection or for the connection of
flexible cables with end sleeves:
Installing
5.4 Connecting the converter and the motor
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
101