![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 269](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045269.webp)
Note
SOS: Safe Operating Stop
p9531[0...3]
SI Motion SLS limit values
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.00 [mm/min]
Max: 1000000.00 [mm/min]
Def: 2000.00 [mm/min]
Description:
Sets the limit values for the function "SLS" function.
Index:
[0] = Limit value SLS1
[1] = Limit value SLS2
[2] = Limit value SLS3
[3] = Limit value SLS4
Dependency:
See also: p9563
See also: C01714
Note
SLS: Safely Limited Speed
p9533
SI Motion SLS setpoint speed limiting
Changeable: T, U
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.000 [%]
Max: 100.000 [%]
Def: 80.000 [%]
Description:
This is an evaluation factor to define the setpoint limit from the selected actual speed limit.
The active SLS limit value is evaluated with this factor and is made available as setpoint limit in r9733.
Dependency:
This parameter only has to be parameterized for the motion monitoring functions integrated in the drive (p9601.2 = 1)
r9733[0] = p9531[x] x p9533 (converted from the load side to the motor side)
r9733[1] = - p9531[x] x p9533 (converted from the load side to the motor side)
[x] = Selected SLS stage
Conversion factor from the motor side to the load side:
- motor type = rotary and axis type = linear: p9522 / (p9521 x p9520)
- otherwise: p9522 / p9521
See also: p9501, p9531, p9601
Note
The active actual speed limit is selected via safety-relevant inputs.
When selecting SOS or a STOP A ... D, setpoint 0 is specified in r9733.
SLS: Safely Limited Speed
p9539[0...7]
SI Motion gearbox direction of rotation reversal
Changeable: C2(95)
Data type: Integer16
P group: Safety Integrated
Min: 0
Max: 1
Def: 0
Description:
Sets the direction of rotation reversal for the gearbox.
0: No direction of rotation reversal
1: Direction of rotation reversal
Index:
[0] = Gearbox 1
[1...7] = Reserved
Dependency:
See also: p9521
p9542
SI Motion actual value comparison tolerance (cross-check)
Changeable: C2(95)
Data type: FloatingPoint32
P group: Safety Integrated
Min: 0.0010 [mm]
Max: 360.0000 [mm]
Def: 0.1000 [mm]
Description:
Sets the tolerance for the data cross-check of the actual position between the two monitoring channels.
Dependency:
See also: C01711
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
267
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...
Page 767: ......