![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 229](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045229.webp)
Data type
The following data types are available for the parameters:
● Integer8
I8
8-bit integer
● Integer16
I16
16-bit integer
● Integer32
I32
32-bit integer
● Unsigned8
U8
8-bit without sign
● Unsigned16
U16
16-bit without sign
● Unsigned32
U32
32-bit without sign
● FloatingPoint32
Float
32-bit floating-point number
P group
Specifies the functional group to which this parameter belongs.
Scaling
Specification of the reference variable with which a signal value is automatically converted
with a BICO interconnection.
The following reference variables are available:
● p2000 … p2003: Reference speed, reference voltage, etc.
● PERCENT: 1.0 = 100%
● 4000H: 4000 hex = 100% (word) or 4000 0000 hex = 100% (double word)
Parameter values
● Min
Minimum value of the parameter [unit]
● Max
Maximum value of the parameter [unit]
● Def
Value when delivered [unit]
Parameters
12.1 Parameter overview
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
227
Summary of Contents for SIMOTICS S-1FK2