![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 266](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045266.webp)
Note
SS1: Safe Stop 1 (corresponds to Stop Category 1 acc. to EN60204)
SS1E: Safe Stop 1 external (Safe Stop 1 with external stop)
For bit 00:
When the function is activated, a safety-relevant acknowledgment (internal event acknowledge) can be performed by
selecting/deselecting STO.
For bit 01:
When the function is activated, the active setpoint velocity limit (CO: r9733) is set to zero when STOP F is active.
For bit 03:
When the bit is activated – when selecting function SS1 or activating a STOP B – an SS1E or a STOP B with Stop,
which should be externally initiated, is triggered instead of SS1 with a drive-based braking response. As a
consequence, brake monitoring (SBR, SAM) is deactivated.
p9513
SI Motion non safety-relevant measuring steps POS1
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: 0
Max: 4294967295
Def: 22000
Description:
Sets the non safety-relevant measuring steps of position value POS1.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Dependency:
See also: F01670
Note
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9513 is automatically set when the system powers up.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9513 is checked to see that it matches the encoder.
p9515
SI Motion encoder coarse position value configuration
Changeable: C2(95)
Data type: Unsigned32
P group: Safety Integrated
Min: -
Max: -
Def: 0000 0000 0000 0000 0000 0000
0000 0000 bin
Description:
Sets the encoder configuration for the redundant coarse position value.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Incrementer
Yes
No
-
01
Encoder CRC least significant byte first
Yes
No
-
02
Redundant coarse position val. most significant bit left-alignedYes
No
-
04
Binary comparison not possible
Yes
No
-
05
Single-channel encoder
Yes
No
-
16
DRIVE-CLiQ encoder
Yes
No
-
Note
- after starting the copy function (p9700 = 57 hex), p9515.0...5 are set according to the encoder.
For safe functions that are not enabled (p9501 = 0), the following applies:
- p9515.16 is automatically set when the system powers up.
For safety functions that are enabled (p9501 > 0), the following applies:
- p9515.16 is checked to see that it matches the encoder.
p9516
SI Motion encoder configuration safety functions
Changeable: C2(95)
Data type: Unsigned16
P group: Safety Integrated
Min: -
Max: -
Def: 0000 0000 bin
Description:
Sets the configuration for the motor encoder and position actual value.
The encoder that is used for the safe motion monitoring function must be parameterized in this parameter.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
264
Operating Instructions, 12/2017, A5E41702836B AA
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...