![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 286](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045286.webp)
Dependency:
See also: r9768
Note
The PROFIsafe trailer at the end of the telegram is also displayed (2 words).
r9770[0...3]
SI version safety functions integrated in the drive
Data type: Unsigned16
P group: Safety Integrated
Description:
Displays the Safety Integrated version for the drive-integrated safety functions
Index:
[0] = Safety Version (major release)
[1] = Safety Version (minor release)
[2] = Safety Version (baselevel or patch)
[3] = Safety Version (hotfix)
Note
Example:
r9770[0] = 5, r9770[1] = 10, r9770[2] = 1, r9770[3] = 0 --> safety version V05.10.01.00
r9776
SI diagnostics
Data type: Unsigned32
P group: Safety Integrated
Description:
Displays the operating state, referred to the safety functions.
Bit field:
Bit
Signal name
1 signal
0 signal
FP
00
Safety parameter changed POWER ON required
Yes
No
-
01
Safety functions enabled
Yes
No
-
02
Safety component replaced and data save required
Yes
No
-
03
Safety component replaced and acknowledge/save required Yes
No
-
Note
For bit 00 = 1:
At least one Safety parameter has been changed that will only take effect after a POWER ON.
For bit 01 = 1:
Safety functions (basic functions or extended functions) have been enabled and are active.
For bit 02 = 1:
A safety-relevant component has been replaced. Saving required (p0977 = 1).
For bit 03 = 1:
A safety-relevant component has been replaced. Acknowledging (p9702 = 29) and saving (p0977 = 1) required.
r9781[0...1]
SI checksum to check changes
Data type: Unsigned32
P group: Safety Integrated
Description:
Displays the checksum to track changes for safety functions.
Index:
[0] = SI checksum to track functional changes
[1] = SI checksum to track hardware-specific changes
Dependency:
See also: p9601
See also: F01690
Note
The checksum changes when configuring safety functions.
r9782[0...1]
SI change control time stamp
Data type: FloatingPoint32
P group: Safety Integrated
Description:
Displays the time stamps for the checksums for tracking changes for safety functions.
Each new checksum is assigned a time stamp (r9781).
Index:
[0] = SI time stamp for checksum to track functional changes
[1] = SI time stamp for checksum to track hardware-specific changes
Parameters
12.2 List of parameters
SINAMICS S210 servo drive system
284
Operating Instructions, 12/2017, A5E41702836B AA