![Siemens SIMOTICS S-1FK2 Operating Instructions Manual Download Page 444](http://html.mh-extra.com/html/siemens/simotics-s-1fk2/simotics-s-1fk2_operating-instructions-manual_379045444.webp)
N07415 (F)
Drive: Angular commutation offset transfer running
Message value:
-
Drive object:
All objects
Reaction:
OFF2
Acknowledge:
NONE
Cause:
The angular commutation offset was automatically determined using p1990 = 1.
This fault causes the pulses to be suppressed - this is necessary to transfer the angular commutation offset to p0431.
Remedy:
The fault can be acknowledged without any additional measures.
Reaction upon F: OFF2
Acknowl. upon F: IMMEDIATELY
F07419
Drive: Current setpoint filter adaptation error
Message value:
%1
Drive object:
All objects
Reaction:
OFF1 (OFF2, OFF3)
Acknowledge:
IMMEDIATELY
Cause:
An error has occurred when configuring or when using the "Current setpoint filter adaptation" function.
Fault value (r0949, interpret binary):
Bit 0: a filter has still not been assigned (p5281).
Bit 1: the assigned filter belongs to the "Extended current setpoint filter" function module that has not been activated
(r0108.21).
Bit 2: the assigned filter is a type or has a characteristic, which is unsuitable for adaptation.
Bit 3: the assigned filter has not been activated (p1656, p5200).
Bit 4 ... 15: internal fault occurred.
Bit 16 ... 31: number of the drive data set with fault.
Remedy:
The message can always be removed by deactivating adaptation (p5280 = 0, -1).
If adaptation is to remain active, then the countermeasure should be applied depending on the particular fault value.
For bit 0:
Assign the filter (p5281).
For bit 1:
activate the "Extended current setpoint filter" function module (r0108.21).
For bit 2:
Set the filter type "General filter 2nd order" and set the characteristic of a bandstop filter.
For bit 3:
Activate filter (p1656, p5200).
For bits 4 ... 15:
- carry out a POWER ON (switch-off/switch-on) for all components.
- upgrade firmware to later version.
F07420
Drive: Current setpoint filter natural frequency > Shannon frequency
Message value:
%1
Drive object:
All objects
Reaction:
NONE (OFF1, OFF2, OFF3)
Acknowledge:
IMMEDIATELY (POWER ON)
Faults and alarms
13.2 List of faults and alarms
SINAMICS S210 servo drive system
442
Operating Instructions, 12/2017, A5E41702836B AA
Summary of Contents for SIMOTICS S-1FK2
Page 2: ......
Page 766: ...Index SINAMICS S210 servo drive system 764 Operating Instructions 12 2017 A5E41702836B AA ...