6.8
Safety settings
6.8.1
Safety commissioning
6.8.1.1
Overview
The web server provides you with a commissioning Wizard that navigates you through all of
the steps required when commissioning safety. The basic handling is shown in the following
diagram:
①
Wizard with commissioning steps
②
Access to fault and alarm messages
③
Safety password
④
Start and carry out Safety commissioning
⑤
Selection for controlling the safety functions
⑥
Selects the safety functions
⑦
Activation of the read-only mode (prevents inadvertent changes)
Figure 6-19
Overview: Safety commissioning Wizard
Basic information on commissioning Safety in the web server
● Safety settings can only be made in the "Safety Integrated commissioning" mode. The
converter is in a safe state (STO active) as long as the commissioning mode is active.
The commissioning mode is activated in step "Function selection" using the "Start" button.
● Safety settings are carried out step-by-step in the individual screen forms. A green
checkmark indicates that a commissioning step has been completed.
Commissioning and diagnostics in the Web server
6.8 Safety settings
SINAMICS S210 servo drive system
Operating Instructions, 12/2017, A5E41702836B AA
135