Section 22 Electrical Characteristics
Rev. 2.00 Mar 09, 2006 page 816 of 906
REJ09B0292-0200
22.3
AC Characteristics
In principle, input is synchronous. Unless specified otherwise, ensure that the setup time and hold
times for each input signal are observed.
Table 22.4 Maximum Operating Frequencies
Conditions: V
CC
= PLLV
CC
= 3.3 V ±0.3 V, PV
CC
= 5.0 V ± 0.5 V/3.3 V ±0.3 V, PV
CC
≥
V
CC
,
V
SS
= PV
SS
= PLLV
SS
= 0 V, Ta = –20 to +75°C
Item
Symbol
Min
Typ
Max
Unit
Notes
Operating
CPU, DSP
f
1
—
62.5
MHz
t
Icyc
frequency
External bus
(SDRAM not used)
1
—
31.25
t
Ecyc
External bus
(SDRAM used)
1
—
62.5
t
Ecyc
Peripheral modules
1
—
31.25
t
Pcyc