Section 14 Serial Communication Interface with FIFO (SCIF)
Rev. 2.00 Mar 09, 2006 page 606 of 906
REJ09B0292-0200
Transmitting
station
Receiving
station A
(ID = 01)
(ID = 02)
(ID = 03)
(ID = 04)
Serial communication line
Serial
data
ID transmission cycle:
Receiving station
specification
Data transmission cycle:
Data transmission
to receiving station
specified by ID
(MPB = 1)
(MPB = 0)
H'01
H'AA
Legend
MPB: Multiprocessor bit
Receiving
station B
Receiving
station C
Receiving
station D
Figure 14.11 Example of Inter-Processor Communication Using Multiprocessor Format
(Transmission of Data H'AA to Receiving Station A)
Transmit/Receive Formats:
There are four transmit/receive formats. When the multiprocessor
format is specified, the parity bit specification is invalid. For details, see table 14.10.
Clock:
See the section on asynchronous mode.
Data Transmit/Receive Operations
•
SCI Initialization
See the section on asynchronous mode.
•
Multiprocessor Serial Data Transmission
Figure 14.12 shows a sample flowchart for multiprocessor serial data transmission.
Use the following procedure for multiprocessor serial data transmission after enabling the
SCIF for transmission.
Summary of Contents for SH7616
Page 10: ...Rev 2 00 Mar 09 2006 page x of xxvi ...
Page 132: ...Section 2 CPU Rev 2 00 Mar 09 2006 page 106 of 906 REJ09B0292 0200 ...
Page 568: ...Section 12 16 Bit Free Running Timer FRT Rev 2 00 Mar 09 2006 page 542 of 906 REJ09B0292 0200 ...
Page 582: ...Section 13 Watchdog Timer WDT Rev 2 00 Mar 09 2006 page 556 of 906 REJ09B0292 0200 ...
Page 706: ...Section 16 Serial I O SIO Rev 2 00 Mar 09 2006 page 680 of 906 REJ09B0292 0200 ...
Page 820: ...Section 19 Pin Function Controller PFC Rev 2 00 Mar 09 2006 page 794 of 906 REJ09B0292 0200 ...
Page 932: ...Appendix D Package Dimensions Rev 2 00 Mar 09 2006 page 906 of 906 REJ09B0292 0200 ...
Page 935: ...SH7616 Hardware Manual ...