![background image](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370017.webp)
1-2
Section
System Configuration
3
Type of data
Number of data items per axis
Positioning sequences, speeds, positions
100
Acceleration times, deceleration times
9
Dwell times
19
Zones
3
These data items are transferred to the PCU for use. Once they have been trans-
ferred to the PCU they can be saved to the PCU’s flash memory, so there is no
need for battery maintenance.
Note
There is a limit to the service life of the flash memory. A total of up to 100,000 data
saving operations can be performed.
The PCU is compatible with the Windows-based NC Support Tool (CX-Position)
that enables setting of the PCUs in a Windows environment. Using the
CS1-series single-port multi-access function, creation and transfer of parame-
ters and data for PCUs as well as operation monitoring are possible from the
same environment as the software used for CPU Unit ladder programming (CX-
Programmer).
1-2
System Configuration
The PCU receives control signals (CW limit, CCW limit, origin, origin proximity,
emergency stop, and external interrupt input signals) from devices and a control
panel, and outputs pulse trains to stepping motor drivers and servo motor drives.
CX-Position
(Available Soon)