![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 153](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370153.webp)
6-4
Section
Origin Search Operation
142
Origin detection method
Origin search operation
0: Reversal mode 1
2: Origin proximity input signal not
used
Note
If the direction of operation is reversed, the reverse will be sudden, without
deceleration or acceleration.
Origin input signal
Pulse output
Origin search proximity speed
Start
Stop
CW limit (See note.)
Start
Stop
Start
Stop
0
3: Limit input signal used instead of
origin proximity input signal
An origin detection method error (error code 1607) is generated and settings are
not possible.
Origin detection method
Origin search operation
1: Reversal mode 2
0: Takes origin signal after origin
proximity signal turns ON (
↑
) and
OFF (
↓
).
Note
A limit signal is input and operation is stopped without deceleration.
Origin proximity input
signal
Origin input signal
Pulse output
Start
Stop
Stop
Start
CW limit (See note.)
Start Limit Stop
(Error code 6200)