9-6
Section
Override
221
•
Beginning word of the common parameter area, m = 100
×
unit num-
ber
•
Beginning word of the operating data area, l, is specified in m and m+1.
Set the beginning words of the operating data area and designate the axis
parameters used with the common parameters as shown below.
Word
Name
Bit
Reference
m
Operating data
area designation
00 to 15
Section 4
m+1
Beginning word of
operating data
area
00 to 15
m+2
Axis parameter
designation
00 to 15
9-6-3 Operating Memory Area Allocation and Operating Data Area
Settings
Operating Memory Area
Name
Model
Operating memory area
Bit
Details
X
axis
Y
axis
Z
axis
U
axis
Override
Enable Bit
NC4
j
3
NC2
j
3
NC1
j
3
n
n
n
n+2
n+2
n+4
n+6
14
1: Enable; 0: Disable
Operating Data Area
Name
Model
Operating data area
Bit
Data configuration
X
axis
Y
axis
Z
axis
U
axis
g
Speed
NC4
j
3
NC2
j
3
NC1
j
3
I+10
I+11
I+10
I+11
I+10
I+11
I+22
I+23
I+22
I+23
I+34
I+35
I+46
I+47
00 to 15
(rightmost)
00 to 15
(leftmost)
15
00
Leftmost
15
00
Rightmost
Setting range:
1 to 7A120 Hex
(1 to 500,000 pps)
Override
NC4
j
3
NC2
j
3
NC1
j
3
I+17
I+17
I+17
I+29
I+29
I+41 I+53 00 to 15
15
00
Override (%)
Set the override in the range
0001 to 03E7 Hex (1 to 999%).