![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 305](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370305.webp)
11-5
Section
Error Code Lists
295
Group
Operation after
error
Clearing method
Cause
Code
Name
Sensor inputs Emergency stop
input
6000
The axis was stopped by an
emergency stop signal input.
Start operation
again after clearing
the emergency
stop input and
executing
RELEASE
PROHIBIT/ERROR
RESET.
An emergency
stop will be
performed on the
affected axis.
Other operating
axes will not be
affected.
CW limit stop
6100
The axis was stopped by a CW
limit input signal.
Move in the CCW
direction after
executing
RELEASE
PROHIBIT/ERROR
RESET.
CCW limit stop
6101
The axis was stopped by a CCW
limit input signal.
Move in the CW
direction after
executing
RELEASE
PROHIBIT/ERROR
RESET.
Origin search No origin
proximity input
signal
6200
The Unit is set for a proximity
input signal, but no origin
proximity input signal was
received during the origin search.
Perform the origin
search again after
checking the origin
proximity input
signal wiring and
the origin proximity
input signal type
(N.C. or N.O.) in
the axis
parameters’ I/O
settings. If the
signal type is
changed, reset the
power supply or
restart the PCU
before resuming
operation.
Other operating
axes will not be
affected.
No origin input
signal
6201
There was no origin input signal
received during the origin search.
Perform the origin
search again after
checking the origin
input signal wiring
and the origin input
signal type (N.C. or
N.O.) in the axis
parameters’ I/O
settings. If the
signal type is
changed, reset the
power supply or
restart the PCU
before resuming
operation.