7-4
Section
Operations With Direct Operation
162
Multiple reversals may not be possible if they are generated while a reversal
operation is already being performed.
Without Reversal
With Reversal
Speed
Speed
New command (CHANGE POSITION)
Start
First specified
position
New specified
position
CW position
CW position
New command (CHANGE POSITION)
Start
First specified
position
New specified position
If the value of the RELATIVE MOVEMENT command causes a reverse, an
emergency reverse will occur when the command is received.
Without Reversal
With Reversal
Speed
Speed
New command (CHANGE POSITION)
Start
First specified
position
New specified
position
CW position
CW position
New command (CHANGE POSITION)
Start
First specified
position
New specified position
If the following operations are performed during pulse output, the pulse output
will stop immediately.
•
Pulse output will stop if 0 is specified for a relative positioning operation with
the origin not established.
•
Pulse output will stop if 0 is specified for either an absolute or relative position-
ing operation when the software limit function is disabled.
The present position at this time (i.e., when pulse output stops) will be equal to
the number of pulses actually output. If any of the above operations are per-
formed after pulse output has stopped, the present position will be taken to be 0.
Summary of Contents for CS1W-NC113 - REV 02-2008