![Omron CS1W-NC113 - REV 02-2008 Manual Download Page 254](http://html1.mh-extra.com/html/omron/cs1w-nc113-rev-02-2008/cs1w-nc113-rev-02-2008_manual_742370254.webp)
10-2
Section
Memory Operation
244
Address
Setting
Contents of setting
112C
0096
Speed #0
150 pps (96 Hex)
112D
0000
p
pp (
)
112E
012C
Speed #1
300 pps (12C Hex)
112F
0000
p
pp (
)
1130
0190
Speed #2
400 pps (190 Hex)
1131
0000
p
pp (
)
1132
01F4
Speed #3
500 pps (1F4 Hex)
1133
0000
p
pp (
)
1134
0000
Speed #4
0 pps (0 Hex)
1135
0000
p
pp (
)
Note
Addresses other than the above should be set to their default settings (0).
Address
Setting
Contents of settings
11F4
03E8
Position #0
1,000 pulses (3E8 Hex)
11F5
0000
,
p
(
)
11F6
08CA
Position #1
2,250 pulses (8CA Hex)
11F7
0000
,
p
(
)
11F8
0CB2
Position #2
3,250 pulses (CB2 Hex)
11F9
0000
,
p
(
)
11FA
1194
Position #3
4,500 pulses (1194 Hex)
11FB
0000
,
p
(
)
11FC
03E8
Position #4
1,000 pulses (3E8 Hex)
11FD
0000
,
p
(
)
11FE
0000
Position #5
0 pulses (0 Hex)
11FF
0000
p
(
)
Note
Addresses other than the above should be set to their default settings (0).
Address
Setting
Contents of settings
12BE
0005
Acceleration time #1
5 ms (5 Hex)
12BF
0000
(
)
12C0
0014
Acceleration time #2
20 ms (14 Hex)
12C1
0000
(
)
12D2
0005
Deceleration time #1
5 ms (5 Hex)
12D3
0000
(
)
12D4
0014
Deceleration time #2
20 ms (14 Hex)
12D5
0000
(
)
Note
Addresses other than the above should be set to their default settings (0).
Dwell times are not used in these programs, so this data area needs to be set
completely to the default settings (0).
Zones are not used in these programs, so this data area needs to be set com-
pletely to the default settings (0).
Speeds
Positions
Acceleration and
Deceleration Times
Dwell Times
Zones
Summary of Contents for CS1W-NC113 - REV 02-2008
Page 1: ...CS1W NC113 213 413 133 233 433 Position Control Units ...
Page 2: ...iv ...
Page 4: ...vi ...